水封洞库施工期水幕补水量与孔隙水压联动规律

    THE INTERRELATIONSHIP BETWEEN ARTIFICIAL WATER REPLENISHMENT AND PORE WATER PRESSURE DURING THE CONSTRUCTION PERIOD OF THE WATER-SEALED CAVERNS

    • 摘要: 研究水封洞库的水幕补水量与孔隙水压联动规律,有助于深入揭示水力密封机制,并为优化水幕技术参数提供理论依据。依据洞库设计标准,将每条储油洞室每百米补水量小于12.5 m3 ·d-1的区域定义为低渗透区,而将补水量大于或等于该值的区域定义为高渗透区。通过对低渗透区和高渗透区的水幕补水量及孔隙水压进行现场监测,揭示了储油洞室施工期间水幕补水量与孔隙水压之间的联动规律:(1)在低渗透区的开挖过程中,水幕补水量相对稳定,而围岩孔隙水压则显著下降;在高渗透区的开挖过程中,水幕补水量显著增加,而围岩孔隙水压保持不变或略有上升。(2)水幕补水量与孔隙水压的下降幅度及下降持续时间存在负相关性。(3)水幕系统在高渗透区的水封调控效率显著高于低渗透区。为提升低渗透区的水幕补水效率,建议适当减小该区域的水幕孔间距。

       

      Abstract: The study of the relationship between artificial water replenishment and pore water pressure contributes to a deeper understanding of the hydraulic sealing mechanism and the optimization of water curtain technical parameters. According to the design standards for underground caverns, areas where the water replenishment for each oil storage chamber is less than 12.5 m3·d-1 per hundred meters are defined as low permeability zones, while areas with a replenishment volume greater than or equal to this value are classified as high permeability zones. Through field monitoring of artificial water replenishment and pore water pressure in both low and high permeability zones, the following relationships were observed during the construction period of the oil storage caverns: (1)In the excavation process of the low permeability zones, the artificial water replenishment remained relatively stable, while the pore water pressure of the surrounding rock decreased significantly. Conversely, in the high permeability zones, the artificial water replenishment increased significantly, while the pore water pressure remained unchanged or slightly increased. (2)There is a negative correlation between the amount of artificial water replenishment and both the magnitude and duration of the decrease in pore water pressure. (3)The water sealing control efficiency of the water curtain system in high permeability zones is significantly higher than that in low permeability zones. To enhance the artificial water replenishment efficiency in low permeability zones, it is recommended to appropriately reduce the spacing of water curtain boreholes in these regions.

       

    /

    返回文章
    返回